Amit's data tools
LuxPlan
440 sq ft · 150 lux target

20×22 basement:
16 lights

16 fixtures A 20×22 ft basement (440 sq ft) needs approximately 16 recessed lights at 800 lumens each — about 13,001 lumens in total — laid out 4 across by 4 deep.

Space them 5.5 ft apart along the 22 ft wall and 5 ft apart along the 20 ft wall, starting 2.8 ft from the end walls.

Fixtures16at 800 lm each
Total lumens13,001to hit 150 lux
Spacing5.5′× 5′ apart
Wall offset2.8′from the end wall

The ceiling plan

Drawn to scale, with each fixture at its computed position and the pale circles showing roughly where each one lands on the working plane.

22 ft 20 ft 4 across × 4 deep · 5.5 ft × 5 ft apart · 2.8 ft from the end walls

Same room, different fixtures

If you have already chosen a fitting, read across from its lumen output.

Fixture outputRough equivalentFixtures neededSuggested grid
450 lm 40 W incandescent 306 × 5
650 lm 50 W incandescent 205 × 4
800 lm 60 W incandescent 164 × 4
1000 lm 75 W incandescent 124 × 3
1200 lm 100 W incandescent 124 × 3

Fewer, brighter fixtures give more contrast; more, dimmer fixtures give flatter, more even light. Both rows deliver the same total.

How the 16 was calculated

Target illuminance for a basement150 luxpublished range 150–300 lux
Floor area40.9 m²440 sq ft
Mounting height above the working plane8 ft8 ft ceiling, measured to the floor
Room index1.31(L × W) ÷ (Hm × (L + W))
Utilisation factor0.59from the room index, light surfaces
Maintenance factor0.8dirt and lamp depreciation
Lumens required13,001 lm150 × 40.9 ÷ (0.59 × 0.8)
Fixtures at 800 lm16delivering about 148 lux

With no daylight contribution and often dark surfaces, basements usually need more fixtures than the raw calculation suggests.

Other ceiling heights

CeilingFixturesGridSpacingMax spacing
8 ft164 × 45.5′ × 5′10.4′
9 ft164 × 45.5′ × 5′11.7′
10 ft205 × 44.4′ × 5′13′
12 ft205 × 44.4′ × 5′15.6′

Questions

How many recessed lights do I need for a 20x22 basement?

About 16 fixtures at 800 lumens each, arranged 4 across by 4 deep. That gives roughly 148 lux across 440 square feet, against a target of 150 lux for a basement.

How many lumens does a 20x22 basement need?

Roughly 13,001 lumens in total. That comes from 150 lux over 40.9 m², divided by a utilisation factor of 0.59 and a maintenance factor of 0.8 — the light that never reaches the working plane has to be paid for up front.

How far apart should the lights be in a 20x22 room?

5.5 ft apart along the 22 ft wall and 5 ft apart along the 20 ft wall, with the outer row about 2.8 ft in from the end walls — half a spacing. With a 8 ft ceiling the maximum sensible spacing is around 10.4 ft before the floor starts to show scallops.

Does the ceiling height change the answer?

Yes, in two ways. A higher ceiling spreads each fixture's light over a wider area, so fixtures can sit further apart — but it also drops the light level reaching the floor, so a taller room generally needs more total lumens. At 8 ft the room index works out at 1.31, giving a utilisation factor of 0.59.

Computed with the lumen method — see how it works and where it is weak. Planning guidance only, not an electrical design. Fixture counts are a starting point — follow your local wiring rules and use a licensed electrician for the installation.

One family of free data tools