Amit's data tools
LuxPlan
320 sq ft · 150 lux target

16×20 garage:
12 lights

12 fixtures A 16×20 ft garage (320 sq ft) needs approximately 12 recessed lights at 800 lumens each — about 10,094 lumens in total — laid out 4 across by 3 deep.

Space them 5 ft apart along the 20 ft wall and 5.3 ft apart along the 16 ft wall, starting 2.5 ft from the end walls.

Fixtures12at 800 lm each
Total lumens10,094to hit 150 lux
Spacing5′× 5.3′ apart
Wall offset2.5′from the end wall

The ceiling plan

Drawn to scale, with each fixture at its computed position and the pale circles showing roughly where each one lands on the working plane.

20 ft 16 ft 4 across × 3 deep · 5 ft × 5.3 ft apart · 2.5 ft from the end walls

Same room, different fixtures

If you have already chosen a fitting, read across from its lumen output.

Fixture outputRough equivalentFixtures neededSuggested grid
450 lm 40 W incandescent 246 × 4
650 lm 50 W incandescent 164 × 4
800 lm 60 W incandescent 124 × 3
1000 lm 75 W incandescent 124 × 3
1200 lm 100 W incandescent 93 × 3

Fewer, brighter fixtures give more contrast; more, dimmer fixtures give flatter, more even light. Both rows deliver the same total.

How the 12 was calculated

Target illuminance for a garage150 luxpublished range 150–300 lux
Floor area29.7 m²320 sq ft
Mounting height above the working plane8 ft8 ft ceiling, measured to the floor
Room index1.11(L × W) ÷ (Hm × (L + W))
Utilisation factor0.55from the room index, light surfaces
Maintenance factor0.8dirt and lamp depreciation
Lumens required10,094 lm150 × 29.7 ÷ (0.55 × 0.8)
Fixtures at 800 lm12delivering about 143 lux

A plain storage garage sits at the low end; if you actually work on things in there, design for the top of the range or higher.

Other ceiling heights

CeilingFixturesGridSpacingMax spacing
8 ft124 × 35′ × 5.3′10.4′
9 ft124 × 35′ × 5.3′11.7′
10 ft164 × 45′ × 4′13′
12 ft164 × 45′ × 4′15.6′

Questions

How many recessed lights do I need for a 16x20 garage?

About 12 fixtures at 800 lumens each, arranged 4 across by 3 deep. That gives roughly 143 lux across 320 square feet, against a target of 150 lux for a garage.

How many lumens does a 16x20 garage need?

Roughly 10,094 lumens in total. That comes from 150 lux over 29.7 m², divided by a utilisation factor of 0.55 and a maintenance factor of 0.8 — the light that never reaches the working plane has to be paid for up front.

How far apart should the lights be in a 16x20 room?

5 ft apart along the 20 ft wall and 5.3 ft apart along the 16 ft wall, with the outer row about 2.5 ft in from the end walls — half a spacing. With a 8 ft ceiling the maximum sensible spacing is around 10.4 ft before the floor starts to show scallops.

Does the ceiling height change the answer?

Yes, in two ways. A higher ceiling spreads each fixture's light over a wider area, so fixtures can sit further apart — but it also drops the light level reaching the floor, so a taller room generally needs more total lumens. At 8 ft the room index works out at 1.11, giving a utilisation factor of 0.55.

Computed with the lumen method — see how it works and where it is weak. Planning guidance only, not an electrical design. Fixture counts are a starting point — follow your local wiring rules and use a licensed electrician for the installation.

One family of free data tools