Photometric sheet 252 sq ft · 200 lux target

14×18 bathroom:
15 lights

15fixtures A 14×18 ft bathroom (252 sq ft) needs approximately 15 recessed lights at 800 lumens each — about 11,142 lumens in total — laid out 5 across by 3 deep.

Space them 3.6 ft apart along the 18 ft wall and 4.7 ft apart along the 14 ft wall, starting 1.8 ft from the end walls.

Assumed·8 ft ceiling·working plane floor·light surfaces·UF 0.53·MF 0.8

SOURCE·IES lumen-method recommendations·published recommendations, quoted as ranges·REVIEWED JUL 2026

Fittings15at 800 lm each
Installed lumens11,142to hold 200 lux
Centres3.6′× 4.7′ apart
Wall setback1.8′half a spacing

Sheet 01 · layoutWhere the 15 go, and how far the light gets

Drawn to scale from the computed centres. The dashed rings are iso-lux contours: the line each fitting's own light crosses on the way down from 43 lux beneath it.

32 lx21 lx11 lx43 lx 18 ft 14 ft 5 across × 3 deep · 3.6 ft × 4.7 ft apart · 1.8 ft from the end walls
Fitting, 800 lm 32 lx 21 lx 11 lx Contours: one fitting, direct only

Read the contours off any one fitting. Directly beneath it, a 800 lm downlight at 8 ft above the working plane puts about 43 lux on that plane; 8 ft away it is down to 11 lux. The target for a bathroom is 200 lux. No single ring gets anywhere near it, and that is the point of the drawing: the level in the room is built out of overlapping contours plus the light that bounces off the walls and ceiling, which is what the utilisation factor of 0.53 pays for. 15 fittings is the count that closes that gap — it is not the room's area divided by a rule of thumb.

SOURCE·Computed from the lumen method·no dataset, every figure reproducible with a calculator·REVIEWED JUL 2026

How this is worked out

  1. Set the ambient target at 200 lx. The published band for a bathroom is 200–300 lx. The ceiling layer is sized to the bottom of it, because this room has a task layer — under-cabinet, desk or bench — that carries the working plane the rest of the way.
  2. Restate the room in metres, and measure to the plane. 252 sq ft is 23.4 m². Mounting height is taken to the working plane, not the floor: 8 ft under a 8 ft ceiling.
  3. Take the losses off before sizing anything. A room index of 0.98 gives a utilisation factor of 0.53 against light surfaces; the maintenance factor is fixed at 0.8 for dirt and lamp depreciation. Between them 58% of everything the fittings emit never lands on the plane, and it has to be bought up front.
  4. Divide, then fit a grid to the room's own proportions. 11,142 lm required; at 800 lm each that is 13.9 fittings, resolved to 15 in a 5 × 3 grid, because an even grid beats a lopsided one at the same total.
  5. Check it against the spacing criterion. 1.3 × 8 ft allows up to 10.4 ft between fittings. This layout sits at 4.7 ft, inside the limit.
N  = (E × A) / (F × UF × MF)
   = (200 × 23.4) / (800 × 0.53 × 0.8)
   = 13.9 fittings   →   5 × 3 = 15 installed

E0 = F / (π × Hm²)        contour datum, one fitting, direct only
   = 800 / (π × 2.44²)
   = 43 lx on the plane directly beneath a fitting

The whole method, and the four places it is weak →

Sheet 03 · scheduleRe-lamp it: what a brighter fitting buys you

If the fitting is already chosen, read across from its lumen output. Fewer, brighter fittings raise the contour datum and widen the rings; more, dimmer ones flatten the floor.

Same room, re-lamped: five fittings, five counts RECOMMENDATIONS · JUL 2026
Fixture outputRough equivalentFixtures neededSuggested grid
450 lm 40 W incandescent 246 × 4
650 lm 50 W incandescent 205 × 4
800 lm 60 W incandescent 155 × 3
1000 lm 75 W incandescent 124 × 3
1200 lm 100 W incandescent 93 × 3

Fewer, brighter fixtures give more contrast; more, dimmer fixtures give flatter, more even light. Both rows deliver the same total.

SOURCE·Computed from the lumen method·no dataset, every figure reproducible with a calculator·REVIEWED JUL 2026

Sheet 04 · ledgerEvery input behind the 15, line by line

Target illuminance for a bathroom200 luxpublished range 200–300 lux
Floor area23.4 m²252 sq ft
Mounting height above the working plane8 ft8 ft ceiling, measured to the floor
Room index0.98(L × W) ÷ (Hm × (L + W))
Utilisation factor0.53from the room index, light surfaces
Maintenance factor0.8dirt and lamp depreciation
Lumens required11,142 lm200 × 23.4 ÷ (0.53 × 0.8)
Fixtures at 800 lm15delivering about 215 lux

Even light on the face at the mirror matters more than ceiling brightness. Fixtures must carry an IP rating appropriate to their zone.

SOURCE·IES lumen-method recommendations·published recommendations, quoted as ranges·REVIEWED JUL 2026

Sheet 05 · variationRaise the ceiling and the whole sheet moves

A taller ceiling spreads each fitting's contours wider, which permits wider centres — and drops the level on the plane, which asks for more total output. Both at once.

The same 14×18 ft bathroom under four ceilings COMPUTED · JUL 2026
CeilingFixturesGridSpacingMax spacing
8 ft155 × 33.6′ × 4.7′10.4′
9 ft155 × 33.6′ × 4.7′11.7′
10 ft164 × 44.5′ × 3.5′13′
12 ft205 × 43.6′ × 3.5′15.6′

SOURCE·Computed from the lumen method·no dataset, every figure reproducible with a calculator·REVIEWED JUL 2026

Sheet 06 · queriesWhat an electrician asks next

How many recessed lights do I need for a 14x18 bathroom?

About 15 fixtures at 800 lumens each, arranged 5 across by 3 deep. That gives roughly 215 lux across 252 square feet, against a target of 200 lux for a bathroom.

How many lumens does a 14x18 bathroom need?

Roughly 11,142 lumens in total. That comes from 200 lux over 23.4 m², divided by a utilisation factor of 0.53 and a maintenance factor of 0.8 — the light that never reaches the working plane has to be paid for up front.

How far apart should the lights be in a 14x18 room?

3.6 ft apart along the 18 ft wall and 4.7 ft apart along the 14 ft wall, with the outer row about 1.8 ft in from the end walls — half a spacing. With a 8 ft ceiling the maximum sensible spacing is around 10.4 ft before the floor starts to show scallops.

Does the ceiling height change the answer?

Yes, in two ways. A higher ceiling spreads each fixture's light over a wider area, so fixtures can sit further apart — but it also drops the light level reaching the floor, so a taller room generally needs more total lumens. At 8 ft the room index works out at 0.98, giving a utilisation factor of 0.53.

Identical geometry, different target illuminance. The count is the only thing that changes.

Sheet issued for planning only. Method, assumptions and the four places this sheet is weak.

Planning guidance only, not an electrical design. Fixture counts are a starting point — follow your local wiring rules and use a licensed electrician for the installation.