Bathroom lighting

A bathroom is commissioned to 200–300 lux, with the ceiling layer sized to 200. Every common footprint, worked against that figure.

Target · why this figureWhat a bathroom is actually lit to

Even light on the face at the mirror matters more than ceiling brightness. Fixtures must carry an IP rating appropriate to their zone.

SOURCE·IES lumen-method recommendations·published recommendations, quoted as ranges·REVIEWED JUL 2026

Schedule · 60 footprintsEvery footprint, worked at 200 lux

Bathroom fixture counts by footprint COMPUTED · JUL 2026
Room sizeAreaTotal lumensFixturesGrid
8 × 8 ft 64 sq ft3,716 lm42 × 2
8 × 10 ft 80 sq ft4,645 lm63 × 2
8 × 12 ft 96 sq ft5,574 lm63 × 2
9 × 9 ft 81 sq ft4,703 lm62 × 3
9 × 12 ft 108 sq ft6,044 lm93 × 3
10 × 10 ft 100 sq ft5,682 lm93 × 3
10 × 11 ft 110 sq ft6,095 lm93 × 3
10 × 12 ft 120 sq ft6,502 lm93 × 3
10 × 13 ft 130 sq ft6,905 lm93 × 3
10 × 14 ft 140 sq ft7,304 lm93 × 3
10 × 15 ft 150 sq ft7,699 lm124 × 3
10 × 16 ft 160 sq ft8,092 lm124 × 3
10 × 20 ft 200 sq ft9,677 lm124 × 3
11 × 11 ft 121 sq ft6,526 lm93 × 3
11 × 12 ft 132 sq ft6,951 lm93 × 3
11 × 13 ft 143 sq ft7,370 lm93 × 3
11 × 14 ft 154 sq ft7,784 lm93 × 3
12 × 12 ft 144 sq ft7,391 lm93 × 3
12 × 13 ft 156 sq ft7,826 lm93 × 3
12 × 14 ft 168 sq ft8,261 lm93 × 3
12 × 15 ft 180 sq ft8,710 lm124 × 3
12 × 16 ft 192 sq ft9,154 lm124 × 3
12 × 18 ft 216 sq ft10,034 lm124 × 3
12 × 20 ft 240 sq ft10,903 lm155 × 3
12 × 24 ft 288 sq ft12,621 lm186 × 3
13 × 13 ft 169 sq ft8,285 lm93 × 3
13 × 14 ft 182 sq ft8,756 lm124 × 3
13 × 15 ft 195 sq ft9,221 lm124 × 3
13 × 16 ft 208 sq ft9,682 lm124 × 3
14 × 14 ft 196 sq ft9,243 lm123 × 4
14 × 15 ft 210 sq ft9,725 lm124 × 3
14 × 16 ft 224 sq ft10,201 lm124 × 3
14 × 18 ft 252 sq ft11,142 lm155 × 3
14 × 20 ft 280 sq ft12,136 lm155 × 3
15 × 15 ft 225 sq ft10,222 lm123 × 4
15 × 16 ft 240 sq ft10,713 lm164 × 4
15 × 18 ft 270 sq ft11,731 lm164 × 4
15 × 20 ft 300 sq ft12,802 lm164 × 4
16 × 16 ft 256 sq ft11,218 lm164 × 4
16 × 18 ft 288 sq ft12,347 lm164 × 4
16 × 20 ft 320 sq ft13,459 lm205 × 4
16 × 22 ft 352 sq ft14,558 lm205 × 4
16 × 24 ft 384 sq ft15,647 lm205 × 4
17 × 17 ft 289 sq ft12,373 lm164 × 4
18 × 18 ft 324 sq ft13,559 lm164 × 4
18 × 20 ft 360 sq ft14,751 lm205 × 4
18 × 22 ft 396 sq ft15,926 lm205 × 4
18 × 24 ft 432 sq ft17,130 lm205 × 4
20 × 20 ft 400 sq ft16,018 lm204 × 5
20 × 22 ft 440 sq ft17,335 lm255 × 5
20 × 24 ft 480 sq ft18,637 lm255 × 5
20 × 30 ft 600 sq ft22,477 lm287 × 4
22 × 22 ft 484 sq ft18,735 lm255 × 5
22 × 24 ft 528 sq ft20,118 lm255 × 5
24 × 24 ft 576 sq ft21,577 lm305 × 6
24 × 30 ft 720 sq ft26,129 lm357 × 5
25 × 25 ft 625 sq ft23,133 lm305 × 6
26 × 26 ft 676 sq ft24,725 lm305 × 6
28 × 28 ft 784 sq ft28,014 lm366 × 6
30 × 30 ft 900 sq ft31,433 lm426 × 7

At 800 lumens per fixture, 8 ft ceiling. A 12 × 14 ft bathroom is the reference case: 9 fittings, 3 × 3, 4.7′ centres.

SOURCE·Computed from the lumen method·no dataset, every figure reproducible with a calculator·REVIEWED JUL 2026