Amit's data tools
LuxPlan
216 sq ft · 200 lux target

12×18 laundry:
12 lights

12 fixtures A 12×18 ft laundry (216 sq ft) needs approximately 12 recessed lights at 800 lumens each — about 8,248 lumens in total — laid out 4 across by 3 deep.

Space them 4.5 ft apart along the 18 ft wall and 4 ft apart along the 12 ft wall, starting 2.3 ft from the end walls.

Fixtures12at 800 lm each
Total lumens8,248to hit 200 lux
Spacing4.5′× 4′ apart
Wall offset2.3′from the end wall

The ceiling plan

Drawn to scale, with each fixture at its computed position and the pale circles showing roughly where each one lands on the working plane.

18 ft 12 ft 4 across × 3 deep · 4.5 ft × 4 ft apart · 2.3 ft from the end walls

Same room, different fixtures

If you have already chosen a fitting, read across from its lumen output.

Fixture outputRough equivalentFixtures neededSuggested grid
450 lm 40 W incandescent 205 × 4
650 lm 50 W incandescent 124 × 3
800 lm 60 W incandescent 124 × 3
1000 lm 75 W incandescent 84 × 2
1200 lm 100 W incandescent 63 × 2

Fewer, brighter fixtures give more contrast; more, dimmer fixtures give flatter, more even light. Both rows deliver the same total.

How the 12 was calculated

Target illuminance for a laundry200 luxpublished range 200–300 lux
Floor area20.1 m²216 sq ft
Mounting height above the working plane5 ft8 ft ceiling, 3.0 ft working plane
Room index1.43(L × W) ÷ (Hm × (L + W))
Utilisation factor0.61from the room index, light surfaces
Maintenance factor0.8dirt and lamp depreciation
Lumens required8,248 lm200 × 20.1 ÷ (0.61 × 0.8)
Fixtures at 800 lm12delivering about 233 lux

A working room. Treat it closer to a kitchen than to a hallway.

Other ceiling heights

CeilingFixturesGridSpacingMax spacing
8 ft124 × 34.5′ × 4′6.6′
9 ft124 × 34.5′ × 4′7.9′
10 ft124 × 34.5′ × 4′9.2′
12 ft124 × 34.5′ × 4′11.8′

Questions

How many recessed lights do I need for a 12x18 laundry?

About 12 fixtures at 800 lumens each, arranged 4 across by 3 deep. That gives roughly 233 lux across 216 square feet, against a target of 200 lux for a laundry.

How many lumens does a 12x18 laundry need?

Roughly 8,248 lumens in total. That comes from 200 lux over 20.1 m², divided by a utilisation factor of 0.61 and a maintenance factor of 0.8 — the light that never reaches the working plane has to be paid for up front.

How far apart should the lights be in a 12x18 room?

4.5 ft apart along the 18 ft wall and 4 ft apart along the 12 ft wall, with the outer row about 2.3 ft in from the end walls — half a spacing. With a 8 ft ceiling the maximum sensible spacing is around 6.6 ft before the floor starts to show scallops.

Does the ceiling height change the answer?

Yes, in two ways. A higher ceiling spreads each fixture's light over a wider area, so fixtures can sit further apart — but it also drops the light level reaching the floor, so a taller room generally needs more total lumens. At 8 ft the room index works out at 1.43, giving a utilisation factor of 0.61.

Computed with the lumen method — see how it works and where it is weak. Planning guidance only, not an electrical design. Fixture counts are a starting point — follow your local wiring rules and use a licensed electrician for the installation.

One family of free data tools