LuxPlan
130 sq ft · 400 lux target

10×13 workshop:
15 lights

15 fixtures A 10×13 ft workshop (130 sq ft) needs approximately 15 recessed lights at 800 lumens each — about 10,901 lumens in total — laid out 5 across by 3 deep.

Space them 2.6 ft apart along the 13 ft wall and 3.3 ft apart along the 10 ft wall, starting 1.3 ft from the end walls.

Fixtures15at 800 lm each
Total lumens10,901to hit 400 lux
Spacing2.6′× 3.3′ apart
Wall offset1.3′from the end wall

The ceiling plan

Drawn to scale, with each fixture at its computed position and the pale circles showing roughly where each one lands on the working plane.

13 ft 10 ft 5 across × 3 deep · 2.6 ft × 3.3 ft apart · 1.3 ft from the end walls

Same room, different fixtures

If you have already chosen a fitting, read across from its lumen output.

Fixture outputRough equivalentFixtures neededSuggested grid
450 lm 40 W incandescent 246 × 4
650 lm 50 W incandescent 205 × 4
800 lm 60 W incandescent 155 × 3
1000 lm 75 W incandescent 124 × 3
1200 lm 100 W incandescent 93 × 3

Fewer, brighter fixtures give more contrast; more, dimmer fixtures give flatter, more even light. Both rows deliver the same total.

How the 15 was calculated

Target illuminance for a workshop400 luxpublished range 500–750 lux
Floor area12.1 m²130 sq ft
Mounting height above the working plane5 ft8 ft ceiling, 3.0 ft working plane
Room index1.12(L × W) ÷ (Hm × (L + W))
Utilisation factor0.55from the room index, light surfaces
Maintenance factor0.8dirt and lamp depreciation
Lumens required10,901 lm400 × 12.1 ÷ (0.55 × 0.8)
Fixtures at 800 lm15delivering about 440 lux

The highest requirement here. The ceiling is sized to 400 lux with task lighting assumed over the bench — machine and detail work needs both quantity and good colour rendering.

Other ceiling heights

CeilingFixturesGridSpacingMax spacing
8 ft155 × 32.6′ × 3.3′6.6′
9 ft155 × 32.6′ × 3.3′7.9′
10 ft164 × 43.3′ × 2.5′9.2′
12 ft205 × 42.6′ × 2.5′11.8′

Questions

How many recessed lights do I need for a 10x13 workshop?

About 15 fixtures at 800 lumens each, arranged 5 across by 3 deep. That gives roughly 440 lux across 130 square feet, against a target of 400 lux for a workshop.

How many lumens does a 10x13 workshop need?

Roughly 10,901 lumens in total. That comes from 400 lux over 12.1 m², divided by a utilisation factor of 0.55 and a maintenance factor of 0.8 — the light that never reaches the working plane has to be paid for up front.

How far apart should the lights be in a 10x13 room?

2.6 ft apart along the 13 ft wall and 3.3 ft apart along the 10 ft wall, with the outer row about 1.3 ft in from the end walls — half a spacing. With a 8 ft ceiling the maximum sensible spacing is around 6.6 ft before the floor starts to show scallops.

Does the ceiling height change the answer?

Yes, in two ways. A higher ceiling spreads each fixture's light over a wider area, so fixtures can sit further apart — but it also drops the light level reaching the floor, so a taller room generally needs more total lumens. At 8 ft the room index works out at 1.12, giving a utilisation factor of 0.55.

Computed with the lumen method — see how it works and where it is weak. Planning guidance only, not an electrical design. Fixture counts are a starting point — follow your local wiring rules and use a licensed electrician for the installation.