Workshop lighting
A workshop is commissioned to 500–750 lux, with the ceiling layer sized to 400. Every common footprint, worked against that figure.
Target · why this figureWhat a workshop is actually lit to
The highest requirement here. The ceiling is sized to 400 lux with task lighting assumed over the bench — machine and detail work needs both quantity and good colour rendering.
SOURCE·IES lumen-method recommendations·published recommendations, quoted as ranges·REVIEWED JUL 2026
Schedule · 60 footprintsEvery footprint, worked at 400 lux
| Room size | Area | Total lumens | Fixtures | Grid |
|---|---|---|---|---|
| 8 × 8 ft | 64 sq ft | 6,361 lm | 9 | 3 × 3 |
| 8 × 10 ft | 80 sq ft | 7,520 lm | 9 | 3 × 3 |
| 8 × 12 ft | 96 sq ft | 8,654 lm | 12 | 4 × 3 |
| 9 × 9 ft | 81 sq ft | 7,563 lm | 9 | 3 × 3 |
| 9 × 12 ft | 108 sq ft | 9,398 lm | 12 | 4 × 3 |
| 10 × 10 ft | 100 sq ft | 8,811 lm | 12 | 3 × 4 |
| 10 × 11 ft | 110 sq ft | 9,505 lm | 12 | 4 × 3 |
| 10 × 12 ft | 120 sq ft | 10,207 lm | 12 | 4 × 3 |
| 10 × 13 ft | 130 sq ft | 10,901 lm | 15 | 5 × 3 |
| 10 × 14 ft | 140 sq ft | 11,589 lm | 15 | 5 × 3 |
| 10 × 15 ft | 150 sq ft | 12,272 lm | 15 | 5 × 3 |
| 10 × 16 ft | 160 sq ft | 12,952 lm | 15 | 5 × 3 |
| 10 × 20 ft | 200 sq ft | 15,711 lm | 21 | 7 × 3 |
| 11 × 11 ft | 121 sq ft | 10,258 lm | 12 | 3 × 4 |
| 11 × 12 ft | 132 sq ft | 11,000 lm | 16 | 4 × 4 |
| 11 × 13 ft | 143 sq ft | 11,734 lm | 16 | 4 × 4 |
| 11 × 14 ft | 154 sq ft | 12,461 lm | 16 | 4 × 4 |
| 12 × 12 ft | 144 sq ft | 11,782 lm | 16 | 4 × 4 |
| 12 × 13 ft | 156 sq ft | 12,553 lm | 16 | 4 × 4 |
| 12 × 14 ft | 168 sq ft | 13,344 lm | 16 | 4 × 4 |
| 12 × 15 ft | 180 sq ft | 14,140 lm | 20 | 5 × 4 |
| 12 × 16 ft | 192 sq ft | 14,930 lm | 20 | 5 × 4 |
| 12 × 18 ft | 216 sq ft | 16,496 lm | 24 | 6 × 4 |
| 12 × 20 ft | 240 sq ft | 18,047 lm | 24 | 6 × 4 |
| 12 × 24 ft | 288 sq ft | 21,228 lm | 28 | 7 × 4 |
| 13 × 13 ft | 169 sq ft | 13,395 lm | 16 | 4 × 4 |
| 13 × 14 ft | 182 sq ft | 14,240 lm | 20 | 5 × 4 |
| 13 × 15 ft | 195 sq ft | 15,077 lm | 20 | 5 × 4 |
| 13 × 16 ft | 208 sq ft | 15,908 lm | 20 | 5 × 4 |
| 14 × 14 ft | 196 sq ft | 15,126 lm | 20 | 4 × 5 |
| 14 × 15 ft | 210 sq ft | 16,003 lm | 20 | 5 × 4 |
| 14 × 16 ft | 224 sq ft | 16,872 lm | 20 | 5 × 4 |
| 14 × 18 ft | 252 sq ft | 18,663 lm | 24 | 6 × 4 |
| 14 × 20 ft | 280 sq ft | 20,457 lm | 25 | 5 × 5 |
| 15 × 15 ft | 225 sq ft | 16,919 lm | 20 | 4 × 5 |
| 15 × 16 ft | 240 sq ft | 17,864 lm | 25 | 5 × 5 |
| 15 × 18 ft | 270 sq ft | 19,766 lm | 25 | 5 × 5 |
| 15 × 20 ft | 300 sq ft | 21,646 lm | 30 | 6 × 5 |
| 16 × 16 ft | 256 sq ft | 18,869 lm | 25 | 5 × 5 |
| 16 × 18 ft | 288 sq ft | 20,858 lm | 25 | 5 × 5 |
| 16 × 20 ft | 320 sq ft | 22,822 lm | 30 | 6 × 5 |
| 16 × 22 ft | 352 sq ft | 24,765 lm | 30 | 6 × 5 |
| 16 × 24 ft | 384 sq ft | 26,693 lm | 35 | 7 × 5 |
| 17 × 17 ft | 289 sq ft | 20,907 lm | 25 | 5 × 5 |
| 18 × 18 ft | 324 sq ft | 23,013 lm | 30 | 5 × 6 |
| 18 × 20 ft | 360 sq ft | 25,138 lm | 30 | 6 × 5 |
| 18 × 22 ft | 396 sq ft | 27,236 lm | 35 | 7 × 5 |
| 18 × 24 ft | 432 sq ft | 29,379 lm | 36 | 6 × 6 |
| 20 × 20 ft | 400 sq ft | 27,415 lm | 36 | 6 × 6 |
| 20 × 22 ft | 440 sq ft | 29,792 lm | 36 | 6 × 6 |
| 20 × 24 ft | 480 sq ft | 32,178 lm | 42 | 7 × 6 |
| 20 × 30 ft | 600 sq ft | 39,244 lm | 48 | 8 × 6 |
| 22 × 22 ft | 484 sq ft | 32,379 lm | 42 | 6 × 7 |
| 22 × 24 ft | 528 sq ft | 34,941 lm | 45 | 9 × 5 |
| 24 × 24 ft | 576 sq ft | 37,674 lm | 49 | 7 × 7 |
| 24 × 30 ft | 720 sq ft | 45,909 lm | 56 | 8 × 7 |
| 25 × 25 ft | 625 sq ft | 40,428 lm | 54 | 9 × 6 |
| 26 × 26 ft | 676 sq ft | 43,340 lm | 56 | 7 × 8 |
| 28 × 28 ft | 784 sq ft | 49,452 lm | 64 | 8 × 8 |
| 30 × 30 ft | 900 sq ft | 55,867 lm | 72 | 9 × 8 |
At 800 lumens per fixture, 8 ft ceiling. A 12 × 14 ft workshop is the reference case: 16 fittings, 4 × 4, 3.5′ centres.
SOURCE·Computed from the lumen method·no dataset, every figure reproducible with a calculator·REVIEWED JUL 2026